-11%
,

DKG507 Automatic Mains Failure Unit

DATAKOM

Key Features

  • True RMS measurements
  • Dual Genset mutual standby operation
  • Event logging with time stamp and measurement
  • Battery backed-up real-time clock
  • Built-in daily/weekly / monthly exerciser
  • Weekly operation schedule programs
  • Field adjustable parameters
  • RS-232 serial port
  • Free MS-Windows Remote monitoring SW
  • Multiple language support
  • 10ADC relay outputs
  • Configurable analog inputs: 4
  • Configurable digital inputs: 7
  • Configurable relay outputs: 2
  • Total relay outputs: 6
  • I/O expansion capability
  • Plug-in connection system
  • Click Here To Download DKG507 User Manual

 58,000.00  65,000.00

Compare

Buy all Datakom products like generator controllers, energy meters, panel meters, synchronization controllers, auto mains failures (AMF), auto transfer switches (ATS), generator battery chargers, etc, online in Pakistan. You can buy DKG507-MPU OR DKG507-CAN automatic mains failure unit online or by visiting Electronic Power House (EPH) and Tetralink Technologies (TLT) in Lahore who are the authorized distributor of Datakom in Pakistan. All original Datakom products are available at very reasonable and best prices in Pakistan.

Features

  • True RMS measurements
  • ECU connection through J1939 CAN option
  • MPU input option
  • Dual genset mutual standby operation
  • Event logging with time stamp and measurements
  • Battery backed-up real time clock
  • Built-in daily/weekly / monthly exerciser
  • Weekly operation schedule programs
  • Field adjustable parameters
  • RS-232 serial port
  • Free MS-Windows Remote monitoring SW
  • Customer logo display capability
  • 10ADC relay outputs
  • Configurable analog inputs: 4
  • Configurable digital inputs: 7
  • Configurable relay outputs: 2
  • Total relay outputs: 6
  • I/O expansion capability
  • Plug-in connection system

Description

The controller is a comprehensive AMF unit for single genset standby or dual genset mutual standby operations. The unit is available with MPU or CANBUS versions. The CANBUS version connects to ECU controlled electronic engines providing engine control, protection, and instrumentation without extra senders. The unit is able to initiate modem calls and send SMS messages in fault conditions through external modems.
The unit provides a comprehensive set of digitally adjustable timers, threshold levels, input and output configurations, operating sequences, and engine
types. All programs may be modified via front panel pushbuttons, and do not require an external unit. Last 100 faults are stored in the event log file. The event log includes not only the date-time information, but also a comprehensive list of measured genset parameters at the time that the fault has occurred. The WINDOWS based RAINBOW program allows remote monitoring and control. The unit supports MODBUS protocol enabling communication with PLCs and building management systems. The MODBUS protocol is also supported through GSM and PSTN modems.

Click Here To Download DKG507 User Manual

Technical Specifications

brands

DATAKOM

color

Black

Technical Specifications

Alternator voltage: 0 to 300 V-AC Phase to Neutral (0 to 520 V-AC Phase to Phase)
Alternator frequency: 0-100 Hz.
Mains voltage: 0 to 300 V-AC Phase to Neutral (0 to 520 V-AC Phase to Phase)
Mains frequency: 0-100 Hz.
DC Supply range: 9.0 VDC to 33.0 VDC
Cranking dropouts: survives 0 V for 100ms
Typical stand-by current consumption: 100 mADC.
Maximum current consumption: 250 mADC.
Generator/mains contactor outputs: 16 A @ 250 VAC.
DC outputs: 10A @ 28 VDC. relay outputs.
Charge alternator excitation: min 2W.
Magnetic pickup input:: 0.5 ? 30 V-AC.
Magnetic pickup frequency: 10 KHz max.
Current inputs: from current transformers, …/5A. Max load 0.7VA per phase.
Digital inputs: input voltage 0 – 30 VDC. Internally connected to battery positive via 47?000 ohm resistor.
Analog inputs: Resistor input 0 to 5000 ohms connected to the battery negative. Sources 5 mA when
closed to battery negative.
Measurement category: CAT II
Air category: Pollution degree II
Communication port: RS-232. 9600 bauds, no parity, 1 stop bit.
Operating temperature range: -40?C to +70?C (-40 ?F to +158 ?F)
Storage temperature range: -55?C to +80?C (-67?F to +176?F)
Maximum humidity: 95%, non-condensing
Dimensions: 200x148x46mm (WxHxD)
Panel Cut-out dimensions: 176 x 121mm minimum.
Weight: 400 g (approx.)
Case material: High temperature, self extinguishing ABS/PC (UL94-V0)
IP protection: IP65 from front panel, IP30 from the rear

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “DKG507 Automatic Mains Failure Unit”

There are no reviews yet.

You may also like…